Trespa TopLab Plus Installation Guidelines. When removing Trespa TopLab Plus through the pallet or cage, raise & carry.

Trespa TopLab Plus Installation Guidelines. When removing Trespa TopLab Plus through the pallet or cage, raise & carry.

Dont slide or drag an advantage along side distinctive exterior. Keep huge sections from flexing by carrying them vertically. Conserve packaging content, e.g., foam or papers, for restacking unloaded panels. If shipping scratches was seen or suspected , you should never refuse the shipment. Note the destruction throughout the expenses of lading and ask the motorist to signal the balance to accept your notations. Call the cargo business and discover if they wanna examine the shipping. In that case, they might would like you to go away all the packaging undamaged for their inspector to review and probably approve a claim payment.

Storing: Trespa must certanly be retained inside in a dried out, well ventilated place. When stacking screens horizontally, make use of styrofoam spacers permitting environment to disperse. Toplab screens incorporate a safety movies at the top (Peel Coat); allow the movie in place up until the installation is finished to help protect the area from incidental problems by other trades. Remove the movie ahead of customer need.

Rectifying: more secure method of connecting Trespa screens is with blind fastening inside again or underside in the panel. Usage #10, type the, piece material screws, size to prevent at the least 1/8″ (3mm) lacking the finished face. Pre-drill the Trespa with an 11/64″ (4.36 mm) diameter fast exercise little bit. Utilize a spacer block to ensure the drill cannot permeate the finished exterior. Avoiding screws from binding, drill a 7/32″ (5.56 mm) clearance opening when you look at the cabinet, railway, cleat, etc. You should be able to push the screws with a hand screwdriver. If you don’t, expand the 11/64″ (4.36 MM) pilot hole.

A subsurface or sub-top is not needed whenever using 3/4″ (20mm) or 1″ (25mm) depth of countertop content (e.g., plywood or particle panel). Edge banding is not needed nor tend to be Apron sections that ordinarily would be used with Good exterior matertials or article form laminates.

Seams: in which less or minimal seam was ideal, the installer / fabricator can prepare the mating parts for Tight-Joint Fasteners and bisquits or splines; be sure to determine whether high dampness can be encountered as slim panels have actually a capacity to warp under certain problems. Bisquits or splines assist offer an even exterior. Bisquits and splines maybe not furnished with layer resources.

Trespa sections could be seamed making use of a two-part epoxy or polyurethane adhesive (e.g., Smooth-on® epoxy glue). When working with Smooth-on®, mix equal parts of A and B, (1 to at least one ratio). As soon as blended, the glue possess an operating time of about an hour; try not to combine a lot more than may be used at xmeets pulpit any once. Smooth-on can be water soluble while moist. With this working time, surplus glue can be simply removed with a putty knife while the place washed with a damp cloth dipped in acetone, lacquer thin, mineral spirits or denatured alcoholic beverages. After 1 hour the epoxy creates difficult and cannot getting readily removed, very clean each seam immediately! Should you decide want a far more detachable seam product, incorporate a colored silicone polymer glue sealant ( e.g., G. E. “Silpruf” or Dow 786). The least expensive seam is a simple butt joint with sealant or adhesive filling a nominal space of 1/8″ (3 mm); this is readily finished with black colored or coloured ground ground.

Sinks: Either Epoxy resin, Polyethylene / Polypropylene or metal undermount or drop-in sinks can be utilized with Trespa counter supplies. Brackets need fastened into predrilled pilot holes. For undermount or clean drop-in sinks, the cutouts must certanly be cooked within manufacturing premises with finished edges in which needed. If the sink hole cutout needs to be produced in the field or work web site, read “Field Modification” under.

Splashes: Apply two part Epoxy adhesive or silicone towards underside for the as well as side splashes and along seam lines, where expected. Utilize the foam padding, report or cardboard safety about countertop exterior in order to avoid adhesive spilling onto the counter surfacing materials. Apply a tiny bit of silicone polymer with the back section of the splash ahead of installations therefore, the splash remains in a 90 amount place as the glue or silicone polymer set in spot.

Industry adjustment: Sawing: For right slices incorporate a 7-1/4″ (184 mm) diameter 40 tooth, carbide, “multiple chip grind” watched blade in an average hand-held power-saw. One’s teeth should plunge into the good exterior.

Routing: unusual incisions should really be routed, not jig-sawed! Utilize a 3/8″ (9.5 mm) electric router with 3HP minimum. Router pieces should really be double straight-fluted carbide or carbide place. To stop the router base from scraping the Trespa surface, pre-apply a 4″ (100 mm) wide acrylic packing tape. Get rid of the tape immediately after routing. Pull any tape deposit with lacquer finer or acetone, etc which will not damage the Trespa panel.

Drilling: Small diameter gaps are drilled with a regular high-speed twist drill or diamond key bit. For larger openings, a carbider opening saw is advised. Drill to the good face and use a wood panel underneath the hole becoming drilled to prevent “blow-out” in the back side.

Advantage Finishing: Trespa countertop edges can be simply sanded to produce a sleek finished looks. Begin with a 60-80 grit paper or similar diamond pad, to get rid of saw/router markings. Follow that with a 120 resolution sand paper end during the sides. If a smoother complete is, start thinking about 220 resolution doing 440 resolution papers or diamond sanding pads, wet practiced. The 60 and 120 determination software are made out of an orbital energy sander, belt sanders are not recommended. Further usage 220 to 440 resolution and hand sand parallel together with the sides to eliminate 60 & 120 grit sanding swirls.

Ultimately, handful of mild gauge petroleum are rubbed regarding sides with a clean fabric and right away cleaned off to raise the sheen. WD-40 can also be used to darken the Black side best.

The most effective industry leading associated with exposed countertop material should-be complete with a 1/8″ (3.17 mm) bevel or 3/16″ (4.76 mm) radius complete side and eased corners or radiused if preferred, so when exposed on an end. Underneath uncovered side of the table should-be done with a 45 degree chamfer to eradicate any razor-sharp open border.

Top Finishing: Trespa very top ground need special manufacturing plant finishes; cannot outfit, oil, wax or complete in any way. Trespa might cleansed with non-abrasive liquid cleansers or disinfectants. Care and repair should-be performed after spills of toxins, hard liquids, etc.

Abrasion maintenance: sides marks could be repaired such as “Edge Finishing.” Surface scratch fixes rely on intensity. A tiny bit of epoxy adhesive might be combined and toned down to apply straight to the taped off part of repair in the event the scrape and scratching try strong and unattractive. Light scratching may be outfitted with a light layer of a mineral petroleum or WD-40. The ethics from the work surface isn’t impaired or affected with exterior scratching.

Transport and Ordering Details

Trespa TopLab benefit is available in all 50 states, Canada, as well as intercontinental distribution globally. Items comes in unfinished / unfabricated pieces, or cut-to-size sheet products. For further details including individual terms quotes, delivery facts, and direct energy, kindly e mail us via mail or call us at 1-888-501-6596.